High-speed door NOVOSPRINT®
Syncro

Technical data
Tender specifications
References
SyncroSyncro LSyncro XL
Door sizeWidth min./ max. (clear passage width)1.000/ 5.000 mm2.400/ 6.000 mm3.800/ 9.000 mm
Height min./ max. (clear passage height)1.700/ 4.500 mm2.100/ 5.100 mm2.100/ 6.000 mm
Headroom requirement standard min.330 mm330 mm480 mm
Space requirement total depth min. / max.420/ 520 mm-/ 550 mm650/ 690 mm
Space requirement on the motor side / not
on the motor side min.
350/ 350 mm350/ 350 mm525/ 525 mm
Height vision panel lower edge/upper edge
in standard
1.480/ 2.000 mm1.480/ 2.000 mm1.480/ 2.000 mm
Performance dataDesigned for up to ... Opening cycles per year350.000350.000150.000
Continuous operation: Up to ... opening
cycles per hour
12012060
Opening speed max. 5 m/s2,5 m/s2,0 m/s
Operating forces/ Safe opening according to EN 13241-1 compliedcompliedcomplied
Water tightness according to EN 12425Class 0Class 0 Class 0
Resistance to wind load according to EN 12424 up to Class 2Class 2Class 2
Resistance to airborne sound Rw according
to EN ISO 717-1 up to approx.
7 dB5 dB5 dB
Thermal resistance Up according to EN 12428 up to 4,9 W/m²K5,9 W/m²K5,9 W/m²K
Air permeability according to EN 12426 up to Class 0Class 0Class 0
Fire behavior according to DIN 4102-1B1B1B1
Fire behavior according to DIN EN 13501-1B-s2,d0B-s2,d0B-s2,d0
Power supply Standard230 V/ 50 Hz230 V/ 50 Hz400 V/ 50 Hz
Safety devicesOSE as safety edge devicecompliedcompliedcomplied
Light curtain (integrated) as safety edge
device
optionaloptional-
Opening in case of electricity failure
(with emergency opening lever)
compliedcompliedcomplied
Automatic opening in case of electricity
failure
optionaloptionaloptional
Light curtain (mounted in front) for
contactless reversing
optionaloptionaloptional
Sensor solutions for opening and monitoringoptionaloptionaloptional
Optical or acoustic warning signalsoptionaloptionaloptional
Escape and rescue route approval (TÜV tested)complied--