SPACELITE®
HT40 - RC3

Technical data
References
Door sizeWidth min./ max. (clear passage width)1.000/ 5.500 mm
Height min./ max. (clear passage height)1.000/ 8.920 mm
Camber requirement min.700 mm
Space requirement Total depth min./ max.620/ 1.540 mm
Space requirement at side drive side/ non-drive side min.2.000/ 130 mm
Single door leaf Height approx.500 mm
Performance dataDesigned for up to ... Opening cycles per year50.000
Short-time duty: Up to ... Opening cycles per hour20
Opening speed max.40 cm/s
Operating forces/ Safe opening according to EN 13241-1fulfills
Watertightness according to EN 12425Class 2
Resistance to wind load according to EN 12424 up toClass 5
Airborne sound insulation Rw according to EN ISO 717-1 up to approx.21 dB
Thermal resistance Up according to EN 12428 up to1,6 W/m²K
Air permeability according to EN 12426 up toClass 3
Burglary protection according to DIN/ TS 18164RC3
Fire protection class -filling- according to DIN 4102 up toB2
Selectivity number S -filling- (τV/ g-value)1,7
Radar reflection attenuation up to20 dB
Resistance class -filling- according to DIN 356 up toP3A
Mains connection Standard1L/N/PE 230V 50Hz |
3L/N/PE 400V 50 Hz
Safety devicesIntegrated TÜV certified fall protectionfulfills
Mechanical overload protectionfulfills
OSE as closing edge safety devicefulfills
Deferral protectionfulfills
Guide rail closed on three sidesfulfills
Light grid (mounted in front) for contactless reversingoptional
Sensor solutions for opening and monitoringoptional
Visual or audible warning signalsoptional
Special solutionsoptional