Door size |
Width min./ max. (clear passage width) |
1.000/ 5.500 mm |
|
Height min./ max. (clear passage height) |
1.000/ 8.920 mm |
|
Camber requirement min. |
700 mm |
|
Space requirement Total depth min./ max. |
620/ 1.540 mm |
|
Space requirement at side drive side/ non-drive side min. |
2.000/ 130 mm |
|
Single door leaf Height approx. |
500 mm |
Performance data |
Designed for up to ... Opening cycles per year |
50.000 |
|
Short-time duty: Up to ... Opening cycles per hour |
20 |
|
Opening speed max. |
40 cm/s |
|
Operating forces/ Safe opening according to EN 13241-1 |
fulfills |
|
Watertightness according to EN 12425 |
Class 2 |
|
Resistance to wind load according to EN 12424 up to |
Class 5 |
|
Airborne sound insulation Rw according to EN ISO 717-1 up to approx. |
21 dB |
|
Thermal resistance Up according to EN 12428 up to |
1,6 W/m²K |
|
Air permeability according to EN 12426 up to |
Class 3 |
|
Burglary protection according to DIN/ TS 18164 |
RC3 |
|
Fire protection class -filling- according to DIN 4102 up to |
B2 |
|
Selectivity number S -filling- (τV/ g-value) |
1,7 |
|
Radar reflection attenuation up to |
20 dB |
|
Resistance class -filling- according to DIN 356 up to |
P3A |
|
Mains connection Standard |
1L/N/PE 230V 50Hz |
3L/N/PE 400V 50 Hz |
Safety devices |
Integrated TÜV certified fall protection |
fulfills |
|
Mechanical overload protection |
fulfills |
|
OSE as closing edge safety device |
fulfills |
|
Deferral protection |
fulfills |
|
Guide rail closed on three sides |
fulfills |
|
Light grid (mounted in front) for contactless reversing |
optional |
|
Sensor solutions for opening and monitoring |
optional |
|
Visual or audible warning signals |
optional |
Special solutions |
|
optional |