One size larger and of course as individual as your company. Up to 7.5m wide, the optimal solution to separate your hall from unwanted external influences.
HT60 | HT60XL | ||
---|---|---|---|
Gate size | Width min./ max. (clear passage width) | 1.000/ 7.500 mm | 1.000/ 7.500 mm |
Height min./ max. (clear passage height) | 1.000/ 13.000 mm | 1.000/ 13.000 mm | |
Headroom requirement standard min. | 750 mm | 1.250 mm | |
Space requirement Total depth min./ max. | 1.015/ 1.850 mm | 1.015/ 1.850 mm | |
Space requirement on the motor side / not on the motor side min. | 200/ 200 mm | 200/ 200 mm | |
Height vision panel lower edge / upper edge in standard | 500 mm | 1.000 mm | |
Performance data | Designed for up to ... Opening cycles per year | 30.000 | 30.000 |
Continuous operation: Up to ... opening cycles per hour | 10 | 10 | |
Opening speed max. | 14 cm/s | 14 cm/s | |
Operating forces/ Safe opening according to EN 13241-1 | complied | complied | |
Water tightness according to EN 12425 | Class 2 | Class 2 | |
Resistance to wind load according to EN 12424 up to | Class 5 | Class 5 | |
Resistance to airborne sound Rw according to EN ISO 717-1 up to approx. | 23 dB | 23 dB | |
Thermal resistance Up according to EN 12428 up to | 1,1 W/m²K | 1,1 W/m²K | |
Air permeability according to EN 12426 up to | Class 3 | Class 3 | |
Burglary protection according to DIN/ TS 18164 | RC2 | RC2 | |
Fire behavior according to DIN 4102-1 | B2 | B2 | |
Fire behavior according to DIN EN 13501-1 | E | E | |
Power supply Standard | 1L/N/PE 230V 50Hz | 3L/N/PE 400V 50 Hz | 1L/N/PE 230V 50Hz | 3L/N/PE 400V 50 Hz | |
Safety devices | Integrated TÜV certified fall protection | complied | complied |
Mechanical overload protection | complied | complied | |
OSE as safety edge device | complied | complied | |
Anti-lift device | complied | complied | |
Guide rail closed on three sides | complied | complied | |
Light curtain (mounted in front) for contactless reversing | optional | optional | |
Sensor solutions for opening and monitoring | optional | optional | |
Optical or acoustic warning signals | optional | optional | |
Special solutions | optional | optional |