Door size | Width min./ max. (clear passage width) | 900/ 2.650 mm |
Height min./ max. (clear passage height) | 1.700/ 3.500 mm | |
Headroom requirement standard min. | 330 mm | |
Space requirement Total depth min./ max. | 420/ 520 mm | |
Space requirement on the motor side / not on the motor side min. | 350/ 135 mm | |
Height vision panel lower edge/upper edge in standard | 1.480/ 2.000 mm | |
Performance data | Designed for up to ... Opening cycles per year | 350.000 |
Continuous operation: Up to ... opening cycles per hour | 120 | |
Opening speed max. | 2,5 m/s | |
Operating forces/ Safe opening according to EN 13241-1 | complied | |
Water tightness according to EN 12425 | Class 0 | |
Resistance to wind load according to EN 12424 up to | Class 2 | |
Resistance to airborne sound Rw according to EN ISO 717-1 up to approx. | 7 dB | |
Thermal resistance Up according to EN 12428 up to | 4,9 W/m²K | |
Air permeability according to EN 12426 up to | Class 0 | |
Fire behavior according to DIN 4102-1 | B1 | |
Fire behavior according to DIN EN 13501-1 | B-s2,d0 | |
Power supply Standard | 230 V/ 50 Hz | |
Safety devices | OSE as safety edge device | complied |
Light curtain (integrated) as safety edge device | optional | |
Opening in case of power failure (with emergency opening lever) | complied | |
Automatic opening in case of electricity failure | optional | |
Light curtain (mounted in front) for contactless reversing | optional | |
Sensor solutions for opening and monitoring | optional | |
Optical or acoustic warning signals | optional | |
Escape and rescue route approval (TÜV tested) | complied | |
Special solutions | optional |