Door size | Width min./ max. (clear passage width) | 1.000/ 5.500 mm |
Height min./ max. (clear passage height) | 1.000/ 8.920 mm | |
Camber requirement min. | 700 mm | |
Space requirement Total depth min./ max. | 620/ 1.540 mm | |
Space requirement at side drive side/ non-drive side min. | 2.000/ 130 mm | |
Single door leaf Height approx. | 500 mm | |
Performance data | Designed for up to ... Opening cycles per year | 50.000 |
Short-time duty: Up to ... Opening cycles per hour | 20 | |
Opening speed max. | 40 cm/s | |
Operating forces/ Safe opening according to EN 13241-1 | fulfills | |
Watertightness according to EN 12425 | Class 2 | |
Resistance to wind load according to EN 12424 up to | Class 5 | |
Airborne sound insulation Rw according to EN ISO 717-1 up to approx. | 21 dB | |
Thermal resistance Up according to EN 12428 up to | 1,6 W/m²K | |
Air permeability according to EN 12426 up to | Class 3 | |
Burglary protection according to DIN/ TS 18164 | RC3 | |
Fire protection class -filling- according to DIN 4102 up to | B2 | |
Selectivity number S -filling- (τV/ g-value) | 1,7 | |
Radar reflection attenuation up to | 20 dB | |
Resistance class -filling- according to DIN 356 up to | P3A | |
Mains connection Standard | 1L/N/PE 230V 50Hz | 3L/N/PE 400V 50 Hz |
|
Safety devices | Integrated TÜV certified fall protection | fulfills |
Mechanical overload protection | fulfills | |
OSE as closing edge safety device | fulfills | |
Deferral protection | fulfills | |
Guide rail closed on three sides | fulfills | |
Light grid (mounted in front) for contactless reversing | optional | |
Sensor solutions for opening and monitoring | optional | |
Visual or audible warning signals | optional | |
Special solutions | optional |